(Performed by Authorized Personnel Only)
Manufacturer: N/A
Model: N/A
| Potential Energy Hazards | | | ||
| Method of Neutralizing Energy | ||||
| Permits Required |
Lockout (Shut-Down Procedure)
- Place vehicle where it will cause the least interference with other equipment or operations in the area.
- All controls at the off position.
- Starting means rendered inoperative.
- Warning or “OUT OF ORDER” signs placed on the vehicle.
- Power plant stopped or disconnected at the power takeoff.
- Boom lowered to the ground if possible or otherwise secured against dropping.
- Relax all hydraulic cylinders used for boom lift and articulation.
- Relieve hydraulic oil pressure from all hydraulic circuits before loosening or removing hydraulic components.
Start-Up Procedure
- Reinstall all guards
- Remove trapped air from hydraulic system
- Reactivate safety devices
- Remove maintenance equipment
- Remove warning or “OUT OF ORDER” signs.